Subject: regen resistor, regen circuit, regen energy, regen power energ.ind.
During braking, energy from the servo motor is returned to the drive and converted
into heat in the Regen resistor. Operation of the Regen resistor is controlled by the
Regen circuit using thresholds that are adjusted to the main supply voltage that is
configured in the UniLink software. The following is an abbreviated functional
description of the Regen circuit operation.

Individual drive (not coupled through the DC Link circuit) - The circuit starts to
respond at a DC Link voltage of 400V, 720V or 840V (depending on the supply
voltage). If the energy fed back from the servo motor is higher than the preset
Regen power, then the drive issues a "Regen power exceeded" signal and the
Regen circuit will be switched off. Upon the next internal check of the DC Link
voltage, an overvoltage will be detected, the fault relay contact will be opened
and the drive will be switched off with the error message "Overvoltage".

Multiple drives (coupled through the DC Link circuit) - In this case, the Regen
energy is distributed equally among all the drives.

 Enote

link 8.01.2007 14:28 
regen = regeneration = рекуперация
Regen resistor - кривой термин, правильно Тормозной резистор, т.к. он рассеивает мощность
Когда они не могут принять на звено ПТ всю мощность с сервомотора (работающего в генераторном режиме), то подключают тормозной резистор, чтобы напруга в звене ПТ не превысила макс. допустимую

 loh N636635

link 8.01.2007 15:06 
Не понял.
А regen power это "тормозная мощность" (???)
и
"regen circuit" = "тормозная цепь" (???)
Как то не звучит всё это по-русски, sorry.

 Enote

link 8.01.2007 15:19 
рекуперативная мощность и цепь рекуперации
а вот резистора рекуперации не бывает

 