Subject: Reservoir data suggests ... Помогите, пожалуйста, перевести последнее предложение ( Reservoir data suggests ...) в нижеперечисленном.These conditions reflect un-drained seam conditions, and the following conclusions can be made: At depths of less than 250 m, up to 40 m3/sec should be planned for active gate roads, under low permeability conditions If high permeability conditions are confirmed, then 50 m3/sec would be required with consequent high air velocities, or alternatively, pre-drainage would be required earlier from, say 220 m depth Faster panel advance rates will bring about increased gassiness and hence earlier response measures Standard, single auxiliary fans should be adequate to about 250 m depth, beyond which, pre-drainage and/or large double fans may be required, especially under high permeability conditions Reservoir data suggests that inseam drainage, when required, should be achievable in a timely and cost effective manner |
По данным пласта-коллектора предполагается, что.... |
Простите, а что предполагается...? Мне бы до конца предложения. |