DictionaryForumContacts

 terminator1

1 2 all

link 19.08.2015 4:37 
Subject: Зажимное приспособление gen.
привет всем.Как у вас настроение?Помогите мне перевести юзер мануал оф зажимного приспособление.поможете или нет?

 terminator1

link 19.08.2015 4:40 
Features :
1) DXL360S/C: High accuracy ±0.05°, high resolution 0.01°

DXL360: ±0.1°, resolution 0.02°, detail check specification

2) Dual and Single axis with user friendly LCD display angle

3) Rechargeable

4) V Shape metal case for easy to fit at the corner or pipe

5) 5 Side Magnetic base

6) Audible alarming at settable angle range

7) Any angle measurement *DXL360s/c only

8) USB/Bluetooth to pc connection need adapter for DXL360 and DXL360s/c.

Specifications
Accuracy :

DXL360S/C:
0 to 20°: ± (0.05°)
20 to 70°: ± (0.1°)
70 to 90°: ± (0.05°)
DXL360:
0 to 20°: ±(0.1°)
20 to 70°: ±(0.2°)
70 to 90°: ±(0.1°)

Measuring range : *After Calibrated
Single axis : 360°,

Dual
axis : ±40°
Revolution : DXL360S/C : 0.01°
DXL360 : 0.02°
Accuracy *DXL360s/c <50°/s
GYRO Rotation Speed DXL 360/s/d <0/4 Second
Audio Sound 60dB@30cm
Zero offset drift angle per ℃ 0.0058°(typical)
Operating temperature 0 to 50℃
Storage temperature -10 to 60℃

User Interface Mono-color LCD with backlight
Supply Power Rechargeable Li-Polymer 3.7V
Charger port 5V 500mA Mini type-B USB port
Power Consumption Standby : 10uA, Operation : 20mA
Standby Battery Life 4000hours
Operating Battery Life 40 hours
Dimensions (in mm) 70(L) x 70 (W) x 23(H)
Magnetic Base affix at 4 corners
Magnetic Force N48
Weight 120g

Button Functions

Button Function Descriptions
Normal Mode MENU Mode
POWER In normal operation, this button turns the device On/Off Serves as the escape key at menu mode
ZERO When pressed, the current reading is set to zero; subsequent measurements are relative to this reading. The LCD will show the icon to indicate the device is in zero mode.
Press and hold for 3 seconds to enable or disable sound. The icon on LCD will be displaced accordingly. The buzzer alarming could be set at different accuracy level.
Refer to section “Angle Alarming” Serves as the upward key for option selection
HOLD When pressed, the current value will freeze; the unit icon flashes to indicate the
reading is on hold Serves as the downward key at menu mode
SET Press and hold for 3 seconds to enter MENU
mode, for set mode options. Serves as the Set key
ANGLE
*DXL360S/C
only Any angle measurement start button, Refer to section “Any Angle”
Press and hold for 3 seconds to enter MENU
mode, for set mode options. Serves as the Set key

LCD Icons Representations

Battery status indication icons
These icons indicate the battery level. There are 3 levels representing empty, half and full.

In dual-axis mode, the LCD displays the direction of tilt graphically. It
will show as E bubble to display the direction of tilt

Degree mode. Flash when unit is in HOLD mode

Mm/M, the height of one end for 1m long plate
Gradient % mode. Flash when unit is in HOLD mode
Sound Notification on.

Blank as off

Show this logo as relative value is showing. When the Zero button is
pressed, the unit reset current angle to zero.

Direction of tilt icons, show the tilt angle direction

Dual-Axis Mode. Both the X and Y axis angle will be showed. Dual
axis mode measures inclination up to ±40 degree for each axis before it automatically switch to single axis mode

Single Axis Mode. Measure slope up to ±90 degree.
The triangle icon indicates the direction of tilt with respect to the bottom right corner of the unit.

Battery Charging
It has a built in Lithium Ion rechargeable battery. A standard charger is supplied that the input voltage is 110V to 240V AC, 50/60Hz, and the output is 5V DC, 500mA. The charger operating procedure is listed below:
1) Plug the Charger into AC socket, the RED indicator on the charger should turned ON,
2) Plug the USB charging cable to the Charger,
3) Insert the other end of the USD cable to the unit
4) The battery icon on the LCD blinks to indicate charging in process. Upon charging complete, the icon stops blinking.
5) The charging time is approx. 3 hours.
The unit could also be charged by connecting the USB cable to the unit and a computer s USB port. This has the same effect when charging the unit with the provided adaptor.
Note : When the unit is turned OFF, and plug in the USB charge cable, the LCD will no show anything, it is NORMAL. Once the unit is turned ON, the battery icon should flash indicating the unit is in charging mode.

Relative/Absolute Measurement
Relative Measurement LCD Icon :
Absolute Measurement LCD Icon : Blank

Relative and Absolute Mode Switching :
1. Press and release the “ZERO” key to set the relative measurement zero point
2. Press and release the “ZERO” key to cancel the relative zero point and
back to absolute measurement mode.

Hold Function Holding Mode : LCD Icon blinking :

Holding Function :
1. Press and release the “HOLD” key to activate holding function, digit will freeze.
2. Press and release the “HOLD” key to cancel the holding function.

Auto Power Off
For no movement in 30 minutes, the unit will power off. Or we can set to never sleep mode at below instruction. Power auto off setting :
1. Press and hold “SET” / “ANGLE” key and enter MENU mode
2. Select “POWER” by “ZERO” and “HOLD” key, press “SET” key to enter Power mode
3. Scroll “NEVER” or “30MIN” by “ON/OFF” and “HOLD” key
4. Press “SET” key to confirm NEVER or 30MIN (30 minutes) sleep

Restore Factory Setting
When you find that the unit is abnormal, you can restore the unit to factory setting.
All calibration setting will be restored to factory setting.

*Not suggest restore to factory setting in normal status, for accuracy drift, please follow

Calibration . After factory set, please redo calibration to ensure the accuracy.
Restore to factory setting :
1. Press and hold“SET”/“ANGLE”key and enter MENU mode
2. Select“FACTORY SET”by“ZERO”and“HOLD”key, press“SET”key to enter FACTORY SET mode
3. Scroll“YES”or“NO”by“ZERO”and“HOLD”key
4. Press“SET”key to confirm

Angle Alarming
Alarming Mode : LCD Icon :

Alarming Angle setting :
1. Press and hold“SET /“ANGLE”key and enter MENU mode
2. Select“BUZZER”by“ZERO”and“HOLD”key, press“SET”or“ANGLE”key to enter BUZZER setting
3. Press and hold“ZERO”and“HOLD”key for fast scrolling the digit.
4. Press“SET”or“ANGLE”to enter setting value

SINGLE Vertical/Single axis mode alarming angle(Degree)
DUAL . X Horizontal/Dual axis mode X axis alarming angle(Degree)
DUAL . Y Horizontal/Dual axis mode Y axis alarming angle(Degree)
RANGE The range(Degree) that will trigger the audible alarming

For example : SINGLE . set to 20.00 RANGE set to 01.00
While the unit is in +19。 to +21。 or -19。 to -21。 , the unit will
alarm
ACTIVE IN or OUT to set the alarm will alarm in of range or out of range

Calibration
Calibrate the unit, once you found that there is accuracy drift on the unit. You can verify the accuracy at below step :

At Step 1, you measured X and Y value, X1 and Y1
At Step 2, you measured X2 and Y2, in theory X1=-X2, Y1=-Y2.
If the error is too large, you can enter calibration mode to eliminate the error Accuracy drift is causing by large ambient temperature change (5 to 10 Degree
Celsius)
or the unit has been dropped.

Calibration Procedure :
Step 1 : Press and hold the“SET”or“ANGLE”key enter Menu mode. Select “Calibration” mode, press“SET. Place the unit on a flat table (no need perfect level table)
LCD display“CALIBRATION DUAL AXIS PRESS SET, press“SET”and buzzer will beep; wait until the beep sound stop. While the buzzer is beeping keep the unit stable.
Step 2 : Then rotate the unit 180 degree with the other side against the same place .
Press the Set button again, and wait for the beep finished.

Step 3 : LCD display“CALIBRATE HORIZONTAL PRESS SET”. Place the unit horizontal like the picture“STEP 3”and then press“SET”, wait until the beep sound stop. Step 4 : Then rotate the unit 180 degree at the same place. Press the“ZERO”
button again, and wait for the beep finished.

Step 5 : LCD display“CALIBRATE VERITICAL PRESS SET”, mention that the ON/OFF Key at upper side, hold on a flat wall. And then press“SET”Key. Wait for the “Beep”sound stop.
Step 6 : Then rotate the unit 180 degree with the other side against the same place of wall (ON/OFF Key at upper side). Press the Set button again, and wait for the beep finished.
Now, the LCD should go back to the selection menu. The calibration is done, by selecting “Back” to go back for normal operation

ANY ANGLE measurement : *DXL360S/C only
Any angle measurement is using gyro technique.
You can measure the angle between two faces, not only in earth gravity

direction.
1) Press Angle key at the first face, and then rotate slowly and must keep the rotation axis to another testing face
2) It will then show the angle once you not move the unit. The rotation axis :

Any Angle Measurement Method :
Example : Measure angle between two wooden walls is 88.9。

Calibrate Gyro *DXL 360S
1) Place Unit At Flat Table And then Press Set

2) Flip 360 degree in clockwise and then press set Please rotate slowly to increase the accuracy

3) Place unit at flat table and then press set

4) Flip 360 degree counter clockwise and then press set Please rotate slowly to increase the accuracy

PC Communication
It has a PC date logging function.
For DXL360SC you can directly plug the USB cable between PC and protractor by mini USB cable
For DXL360/S You cannot directly plug the USB cable between PC to protractor by a general USB cable.
You need to optional purchase the PC adapter SVRS232
You can continue to data logging X and Y inclination data to PC. Sampling time is around 2 Hz.

Specification :
1. RS232 Com Port 9600 baud rate
2. USB connection (include a RS232 to USB adapter)
3. Format will output ASCII : example for X is 0, Y is -88.88 X+0000Y-8888

Detail can visit our website or contact our sales person.

Get short URL | Pages 1 2 all