DictionaryForumContacts

 france3

link 24.05.2010 9:06 
Subject: sizing on powering
39020 T1 heads not on hold
Cause:
Effect:
Remedy:
Notes:
The [Start button] on Kvara or the production Start button in the Learning menu have been pressed in an attempt to start an automatic axes positioning cycle while at least one of the boring heads was not in the hold position. Or, at least one of the boring heads was not in the hold position during the sizing phase after powering. Or, at least one of the boring heads was not in the hold position during the automatic cycle in a phase that did not concern a machining process No automatic axes positioning cycle can be started Or sizing on powering cannot be accomplished
Or tool change cannot be accomplished. Check the limit switches of axes T1-Z1 and T1-Z2 on hold Check the outputs of the PLC and the actuators involved in the Z1 upper and Z2 lower boring heads plus any mechanical interferences.

заранее спасибо

 Enote

link 24.05.2010 9:32 
sizing on powering - имхо определение координат (размеров?) при включении питания

 

You need to be logged in to post in the forum