Subject: fault electr.eng. О каком "фолте" здесь идет речь? О замыкании? Или о какой-то ошибке (сбое)?The fault restart function will restart the inverter even when an internal fault occurs during inverter operation. Use this function only when continuing operation is more important than possibly damaging the inverter. The fault restart function is effective with the following faults. With other faults, the protective operations will engage immediately without attempting to restart operation. Over-current Ground fault Main circuit over-voltage The fault restart count will automatically increase upon the restart activated and will be cleared in the following cases: a. When the operation is normal for 10 minutes after a fault restart is performed. b. When the fault-reset input is received after the protection operation has been activated and the fault confirmed. (e.g., by pressing RESET or enable Fault reset terminal ) c. When the power is turned off and on again. When one of the multi-function output terminals (RA-RB-RC or R1A-R1B-R1C, DO1, DO2 or R2A-R2C) is set to restart enabled, the output will be ON while the fault restart function is in progress. See page 90 for the setting of (Sn-30~Sn-32). Далее по тексту еще встречается выражение external fault. Сразу спасибо.
|